Installation should be done by a trained technician with a valid certificate issued by an authorized Jablotron distributor.The required settings and system parameters are programmed via MyCOMPANY. The setup is intuitive and very simple even for novice installers.
Instalation type | Fixed instalation |
Control panel power supply / frequency / fuse | ~ 110-230 V/50-60 Hz, max. 0.28 A with F1.6 A/250 V fuse, protection class II |
Power / current | max 23 VA / 0.1 A |
Protection class | II. |
Back-up battery | 12 V; 2.6 Ah max (lead gel) |
Low backup battery voltage (fault indication) | ≤11 V |
Maximum battery recharge time (80% capacity) | 72 h |
Bus supply voltage / max ripple (red - black) | 12.0 ÷ 13.8 VDC / ±100 mV |
Max. continuous consumption from control panel | 1000 mA |
- with 12 h backup (2.6 Ah battery) | Without GSM communicator | LAN - off: 115 mA | LAN - on: 88 mA |
With GSM communicator | LAN - off: 80 mA | LAN - on: 53 mA | |
Max. number of sections | 4 |
Max. number of peripherals | 31 peripherals + 31 drivers |
Max. number of users | 32 |
Max. number of PG outputs | 2 |
Alarm connections | Jablotron bus - dedicated cable connection Wireless connection (with JA-111R) - non-specific wireless connection, wireless Jablotron protocol |
Alarm device classification | Security level 2 / environment class II |
- In accordance with | EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2 |
- Environment | Indoor general |
- Operating temperature/humidity range | -10 °C to +40 °C/75% non-condensing |
- Power supply | Type A - primary power supply with rechargeable backup battery |
- Event memory capacity | of approx. 7 million recent events including source, date and time |
- system response to loss of communication with periphery | Fault or Sabotage - depending on settings and profile bus up to 10 s wireless communication up to 2 h (since last communication) wireless communication within 20 min prevents securing the section |
- System reaction to incorrectly entered codes | after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes. |
- ATS classification | Supported ATS classes: SP2 - SP5, DP2 - DP4 SPT: Type Z Type of operation: Pass-through LAN on board: SP2 - SP5 (with IP protocol) JA-194Y LITE SP3 - SP5 (JABLO IP, ANSI SIA, DC-09) LAN + JA-194Y LITE DP2 - DP4 JABLO IP, ANSI SIA, DC-09) |
- ATS alarm transmission protocols | JABLO IP, SIA IP, Contact ID, |
- ATC security against substitution and information protection | Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key DC-09.2012 protocol with 128-bit AES encryption |
LAN communicator | Ethernet interface CAT 5 (RJ-45) |
Dimensions | 268 x 225 x 83 mm |
Weight with/ without ACU | 1809 g/919 g |
Basic parameters of the JA-111R module | 868.1 MHz, <25 mW, GFSK <80 kHz |
Radio emission | ETSI EN 300 220-2 (JA-111R module) |
EMC | EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3 |
Electrical safety | EN IEC 62368-1 |
Conditions of operation of the CTU radio module | ERC REC 70-03 |
Certification body | TREZOR TEST (No. 3025) |