The JA-107K is an advanced version of the JABLOTRON 100+ security system. It is designed for large living spaces, offices and businesses. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.
It also offers flexible protection solutions for residential complexes, administrative buildings and companies that require a multi-section system. The adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).
The JA-107K control panel offers:
The control panel has:
The control panel also offers functions such as:
The following products with the control panel ARE NOT COMPATIBLE:
The following products with the control panel ARE COMPATIBLE under certain conditions:
Control panel power supply | ~ 110 – 230 V/50 – 60 Hz, max. 0.85 A with fuse F1.6 A/250 V, Protection class II |
Back-up battery | 12 V; 7 to 18 Ah (lead gel) |
Maximum battery charging time | 48 h |
BUS voltage (red - black) | 12.0 to 13.8 V |
Maximum continuous current consumption from the control panel | 2000 mA permanent 3000 mA for 60 minutes (max. 2000 mA for one BUS) |
Max. continuous current consumption for back-up 12 hours | Without GSM communicator LAN – OFF: 1135 mA LAN – ON: 1107 mA |
With GSM communicator LAN – OFF: 1100 mA LAN – ON: 1072 mA | |
Max. continuous current consumption for back-up 24 hours | Without GSM communicator LAN – OFF: 535 mA LAN – ON: 499 mA |
With GSM communicator LAN – OFF: 530 mA LAN – ON: 494 mA | |
Maximum number of devices | 230 |
LAN communicator | Ethernet interface, 10/100BASE |
Dimensions | 357 x 297 x 105 mm |
Weight with/without AKU | 7027 g/1809 g |
Reaction to invalid code entry | Alarm after 10 wrong code entries |
Event memory | Approx. 7 million latest events, including date and time |
Power supply unit | Type A according to EN 50131-6 T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC. |
GSM communicator (2G) | 850 / 900 / 1800 / 1900 MHz |
Classification | Security grade 2 according to EN 50131-1 |
Operational environment | Environmental class II (indoor general) according to EN 50131-1 |
Operational temperature range | -10 °C to +40 °C |
Average operational humidity | 75 % RH, non-condensing |
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581 |
Radio operating frequency (with the JA 11xR module) | 868.1 MHz |
Radio emissions | ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM) |
EMC | EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7 |
Safety conformity | EN 62368-1+A11 |
Caller identification (CLIP) | ETSI EN 300 089 |
Operational conditions | ERC REC 70-03 |
Certification body | Trezor Test s.r.o. (no. 3025) |