JA-110B Bus acoustic glass-break detector

JA-110B Bus acoustic glass-break detector

The JA-110B is a bus glass-break detector which recognizes the sounds of smashing window panes. The detection is based on dual technology (detection of changes in air pressure combined with the sound of breaking glass).

Its sensitivity is adjustable. The detector communicates with and is powered by the bus. The detector is addressable, and occupies one position in an alarm system. SMART MEMORY indication (SMI) provides a visual (LED) verification of detector triggering. SMI is reset via the keypad.

Power from the control panel bus 12 V (9… 15 V)
Current consumption in standby mode 5 mA
Current consumption for cable choice 5 mA
Recommended installation height 2.5 m above the floor
Detection distance up to 9 m
Minimum window glass size 0.6 x 0.6 m
Stabilization time after the switching on max. 60 s
Dimensions 40 x 100 x 22 mm
Classification Grade II
according to EN 50131-1, EN CLC/TS 50131-2-7-1
Operational environment according to EN 50131-1 II. Indoor general
Operating temperature range -10 °C to +40 °C
Also complies with EN 50130-4, EN 55022
#

GBT-212 Glass Break Simulator

It is also possible to trigger the sound